Description
ENERDRIVE 200AH OFF-GRID 40A AC & DC CHARGING BUNDLE, WITH 720W OF SOLAR PANELS AND 2000W INVERTER (AC TRANSFER)
505 X 173 X 265MM (BATTERY) | 295MM X 206MM X 90MM (AC BATTERY CHARGER) | 1482 X 680 X 35MM (SOLAR PANELS) | 230 X 435 X 115 MM (INVERTER)
Included:
- Enerdrive ePOWER B-TEC 200Ah Lithium Battery EPL-200BT-12V-G2
- Enerdrive ePOWER 12V 40A DC to DC Battery Charger EN3DC40+
- Enerdrive ePOWER 12V 40A Battery Charger EN31240
- Enerdrive ePRO PLUS Battery Monitor EN55050
- Enerdrive ePOWER 2000W 12V Pure Sine Wave Inverter with RCD & AC Transfer Switch EN1120S-X
- Enerdrive 180W Mono Crystalline Fixed Solar Panel (x4) SP-EN180W
Specifications:
- Amp Hours 200.0 Ah
- Battery Voltage 12V
- Charger Mode Output Voltage 13.8V - 15.5V (DC Battery Charger) | 14.2 – 15.5 V (AC Battery Charger)
- Float 13.50 - 13.80V (Battery) | 13.0V - 13.8V (DC Battery Charger) | 13.4 – 13.8 V (AC Battery Charger)
- Equalize 15.5V (DC Battery Charger) | 16.0 V (AC Battery Charger)
- Charging Control Four stages (Bulk/Absorption/Float/Maintenance), Two stages (Bulk/Absorption)Constant Power Supply (Program setting), Priority Battery Bank Charging (AC Battery Charger
- DC Output Single (DC Battery Charger) | Three (1 fully independent, 2 common with diode isolation) (AC Battery Charger)
- Selectable Battery Type Gel, AGM, Flooded, Lithium, Program (DC and AC Battery Charger)
- Standby Current < 2 mA (AC Battery Charger)
- Cell Type Monocrystalline - 72 Cells each (Solar Panels)
- AC Input Voltage 90 to 265 VAC (AC Battery Charger)
- AC Input Operating Range 207-265 Vac (3.8 A Max)90 – 125 Vac (7.7 A Max) (AC Battery Charger)
- AC Input Frequency Range 47 – 63 Hz (AC Battery Charger)
- Power Consumption 700W (Full Load) (AC Battery Charger)
- Power Factor Correction Yes (AC Battery Charger)
- Charger Efficiency 95% (DC Battery Charger) | > 82% (AC Battery Charger)
- Reverse Polarity Yes, (with user replaceable fuse/s) (AC Battery Charger)
- Over Charge Yes, unit shutdown (AC Battery Charger)
- Over Temperature Protection Yes, unit de-rated and shutdown (AC Battery Charger)
- Cooling Forced air ventilation (thermo controlled fan) (AC Battery Charger)
- Output Short Circuit Yes, (with user replaceable fuse/s) (AC Battery Charger)
- Temperature Setting Low/ Normal/ High (Battery Temperature Sensor Standard) (DC Battery Charger) | Hot, Normal, Cold (no sensor connected) (AC Battery Charger)
- Battery Temperature Sensor Port RJ12 (standard battery temp. sensor supplied) (AC Battery Charger)
- LCD Display Charging status, Battery Voltage, Output Current & Fault Codes (AC Battery Charger)
- AC Input Connection IEC with Supplied 1.2M Power Lead (AC Battery Charger)
- DC Output Connection Heavy Duty Terminal (3 banks) – Pan Heads 6mm Thread (AC Battery Charger)
- DC Output Ground Single Heavy Duty Common Ground Stud (AC Battery Charger)
- Storage Temperature Range -40° to 70° C (AC Battery Charger)
- Operating Temperature Range -20° to 60° C (AC Battery Charger)
- Humidity 5-95%, relative humidity non-condensing (AC Battery Charger)
- Ingress Protection IP32 (Basic drip proof in vertical orientation) (AC Battery Charger)
- Nominal Voltage 12.8V (Battery)
- Nominal Capacity 200Ah (Battery)
- Total Charge Current Max 150A @ 25°C for 30mins (Battery)
- Regulatory Compliance Complies with AS/NZS 60335.2.29 Including Australian deviations
- Cycle Life (DOD - 80% under controlled conditions) ≥ 2000 Cycles (Battery)
- Battery Charge Temperature 0 ̴ 45°C (Battery)
- Normal Charge Voltage CV/CC* 14.40 ̴ 14.60V (Battery)
- Standby (Float) Voltage 13.50 ̴ 13.80V (Battery)
- Maximum Charge Current 150A @ 25°C for 30mins (Battery)
- Recommended Charge Current for Maximum Life ≤ 60A (Battery)
- Battery Discharge Temperature -20 ̴ 60°C (Battery)
- Battery Output Voltage Range 11.00 ̴ 14.60V (Battery)
- Maximum Discharge Current 200A @ 25°C ± 5°C for 30mins (Battery)
- Pulse Discharge Current 450A for 1.0s (Battery)
- Discharge Cut-off Voltage ≤ 11.20V (Battery)
- Input Voltage 12.5 VDC (Inverter)
- AC Output 2000W, 8.7A (Inverter)
- No Load Battery Draw < 1.2 ADC (Inverter)
- Under Voltage Alarm 11.0/12.1 VDC (Inverter)
- Under Voltage Alarm Recovery 11.3/12.3 VDC
- Under Voltage Shutdown 10.5/11.8 VDC (Inverter)
- Under Voltage Shutdown Recovery 12.0/12.6 VDC (Inverter)
- Over Voltage Shutdown 15.5VDC (Inverter)
- USB Socket Output 5V, 750 mA (Inverter)
- Operating Altitude Up to 3000 meters above sea level (Inverter)
- Wattage 180W each (720W toal) (Solar Panels)
- Warranty 5 Years (Battery 5 Years)
Here are 4 more great reasons to buy from us:
![]() |
Returns are easy, simply contact us within 30 days for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! |
|
![]() |
We are 4 wheel drive and camping specalists, we live and breath this and we bring that passion and expertise to everything we do. |
|
![]() |
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. |
|
![]() |
Ordering from Shoptimized is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. |
Postage Time Frames:
As each kit is custom built it may take us some time to process and dispatch your order.
- 2 weeks estimated dispatch time
- Shipping can take 1-2 weeks depending on your location and postal service
If you need your kit within a particular deadline, please contact us prior to ordering so we can ensure your items can arrive on time.